Major Reasons of Ultra-High Sensitivity
and Stability of Eicom ECD

  • Innovative Design of Electrochemical Detector Cell
  • System Design with Pulsation Free Pump
  • Temperature Regulated System with Both Cooler and Heater
  • Optimized Applications for the ECD

as you can see, the sensitivity could not be achieved only by the detector. Please read on for more details.

All-In-One With A Small Footprint

A common sentiment of our users the first time they see our system is, “Is this a complete HPLC-ECD system?
It is so compact!” The HTEC-510 users are always pleasantly surprised with the small footprint. The HTEC-510 includes

  • An online degasser (only 300 µl volume)
  • HPLC pump (no pulsation damper)
  • Manual injector
  • Column temperature controller (both cooling and heating)
  • Electrochemical detector cell

within a single package the size of a typical desktop computer. The trimmed HPLC-ECD did not sacrifice anything in order to combine the latest technology into this concise unit which has enhanced stability. This system actually has higher sensitivity levels than the preceding models, as well as the compact design. Read on to learn the latest technological advancements within the compact design.

Anatomy of the HTEC-510

HPLC-ECD-Electrochemical-Detector-HTEC-500_INTERIOR-anatomy-details

No Pulse Damper Required

Normal HPLC pumps are not ideal for electrochemical detection. The EC detector is sensitive enough to detect pulsation from the pump and therefore, a pulse damper is required to reduce this noise. However, the pulse damper itself can cause problems. It requires more than 10 ml to replace the inside volume. This volume can contribute to contamination following long periods of storage or shipping, and can be a serious problem for detection. The pulse damper needs to be filled completely with mobile phase in order for the pressure to stabilize. It takes more than 5 minutes. If any old mobile phase remained in the system and entered the new column, the upcoming analysis could be ruined. The presence of the pulse damper in the HPLC system was not ideal. So we removed the damper from the system and adopted a 4 µl replacement volume pump. This small binary pump has a computerized pulsation quenching technology. Once you start the pump, the pressure becomes stable in several seconds and the piston-stroke speed changes during each stroke in order to quench pulsation. You can see the spindle-shaped baseline noise will converge to a thin flat line within one minute. The dead volume between the piston and the column is less than 1 ml, making cleaning the line quick and easy.

Directly Attain the Results

We understand you are looking for the best system by investigating a few key aspects of the systems, but is that all you need? You need the RESULTS obtained by the system. Eicom offers a turn-key solution and you can depend on us to get you the data. By telling us the target compounds and type of samples, Eicom will provide dependable application solutions including: detailed application manuals, specially designed columns for the ECD, and technical support. You do not need to take time creating analytical methods or washing the column for a few days prior to kick off a new project. As long as you use Eicom’s HPLC-ECD and our analytical applications, the data will be easily generated. If you’ve never used an ECD or HPLC, starting with the most user-friendly machine is the best way to efficiently achieve your goals.

Summary and Additional Features of the HTEC-510

  • Sensitive
  • Stable
  • Minimal maintenance and more uptime
  • Small footprint
  • Intuitive operation with an integrated control panel
  • The system has inert materials at the liquid contacting surfaces
    which prevents metal ions from flowing to the detector that canresult in noise
  • Powerful applications.
  • Excellent support Learn more